A401 Electronic Crack Meter Logger

Stores up to 64,000 readings, depending on the memory capacity.

550,00

- +
SKU: A401 Category:

Stores up to 64,000 measurement values, depending on the memory capacity.

  • Built-in memory for 16,000 readings (optional memory for up to 64,000 readings)
  • Measurement and storage of the cycle (1 second to 24 hours) freely adjustable via PC software
  • Freely programmable, fully automatic start-stop operation or continuous loop storage
  • Integrated crystal oscillator-controlled real-time clock and real-time calendar
  • Measurement range of the crack sensor: 10 mm (+/- 5 mm)
  • Extended measurement range for the crack sensor, e.g. 75 mm, available as a customised version
  • Resolution of the crack sensor: 2.5 μm = 0.0025 mm = 0.0001 inch
  • Length of the crack sensor cable: 2 m (longer cables of up to 100 metres available on request)
  • High-speed crack monitoring at up to 100 Hz can be activated
  • No mechanical torsion of the sensor thanks to the complete decoupling of the stopper
  • Sensor can be zeroed (tare function) and the system is started via an activation magnet
  • Optional: Combined air temperature and humidity sensor (internal climate sensors) available
  • No calibration of the climate sensors required
  • Measuring range of the air temperature sensor: -20 °C to 70 °C
  • Measuring range of the humidity sensor: 0% RH to 100% RH (dew-free)
  • Resolution of both climate sensors: 0.1 °C / 0.1% RH
  • Accuracy of the air temperature sensor: <0.4 °C at 20 °C
  • Measurement accuracy of the humidity sensor: <3.0% RH between 20% RH and 80% RH
  • Optional: Climate sensor with a measurement accuracy of <1.8% RH and <0.3 °C
  • Repeatability of both climate sensors: 0.1 °C / 0.1% RH
  • Long-term stability of the air temperature sensor: <0.04 °C per year
  • Long-term stability of the humidity sensor: <0.5% RH per year
  • Dew point calculation available via PC software (including for thresholds up to 100% RH)
  • Automatic min/max monitoring for gapless recording of extreme climatic values
  • Alarm output for SMS alarm system, audible alarm system, telephone alarm system, etc.
  • Numerous other external sensors available for the data logger (e.g. 8 x temperature sensors)
  • External connection for four sensors available on request
  • Calibration certificates available on request
  • Measurement data stored via EEPROM memory, even without batteries
  • Powered by two standard AA batteries
  • Battery life of up to two years (see configuration). Batteries can be replaced at any time
  • Shock-resistant and waterproof data logger housing. Wall mounting possible (screws concealed)
  • Data logger dimensions: 88 x 120 x 50 mm (HxWxD)

Data can be read using the software and USB data cable supplied. For further information, please contact s.bakker@bavib.nl

Memory capacity Active sensors Interval Measurement duration
16,000 readings crack sensor 15 minutes 167 days
16,000 readings crack sensor
humidity
air temperature
15 minutes 56 days
16,000 readings crack sensor 1 hour 667 days
16,000 readings crack sensor
humidity
air temperature
1 hour 222 days
64,000 readings crack sensor 15 minutes 667 days
64,000 readings crack sensor
humidity
air temperature
15 minutes 222 days
Delivery method