Stores up to 64,000 measurement values, depending on the memory capacity.
- Built-in memory for 16,000 readings (optional memory for up to 64,000 readings)
- Measurement and storage of the cycle (1 second to 24 hours) freely adjustable via PC software
- Freely programmable, fully automatic start-stop operation or continuous loop storage
- Integrated crystal oscillator-controlled real-time clock and real-time calendar
- Measurement range of the crack sensor: 10 mm (+/- 5 mm)
- Extended measurement range for the crack sensor, e.g. 75 mm, available as a customised version
- Resolution of the crack sensor: 2.5 μm = 0.0025 mm = 0.0001 inch
- Length of the crack sensor cable: 2 m (longer cables of up to 100 metres available on request)
- High-speed crack monitoring at up to 100 Hz can be activated
- No mechanical torsion of the sensor thanks to the complete decoupling of the stopper
- Sensor can be zeroed (tare function) and the system is started via an activation magnet
- Optional: Combined air temperature and humidity sensor (internal climate sensors) available
- No calibration of the climate sensors required
- Measuring range of the air temperature sensor: -20 °C to 70 °C
- Measuring range of the humidity sensor: 0% RH to 100% RH (dew-free)
- Resolution of both climate sensors: 0.1 °C / 0.1% RH
- Accuracy of the air temperature sensor: <0.4 °C at 20 °C
- Measurement accuracy of the humidity sensor: <3.0% RH between 20% RH and 80% RH
- Optional: Climate sensor with a measurement accuracy of <1.8% RH and <0.3 °C
- Repeatability of both climate sensors: 0.1 °C / 0.1% RH
- Long-term stability of the air temperature sensor: <0.04 °C per year
- Long-term stability of the humidity sensor: <0.5% RH per year
- Dew point calculation available via PC software (including for thresholds up to 100% RH)
- Automatic min/max monitoring for gapless recording of extreme climatic values
- Alarm output for SMS alarm system, audible alarm system, telephone alarm system, etc.
- Numerous other external sensors available for the data logger (e.g. 8 x temperature sensors)
- External connection for four sensors available on request
- Calibration certificates available on request
- Measurement data stored via EEPROM memory, even without batteries
- Powered by two standard AA batteries
- Battery life of up to two years (see configuration). Batteries can be replaced at any time
- Shock-resistant and waterproof data logger housing. Wall mounting possible (screws concealed)
- Data logger dimensions: 88 x 120 x 50 mm (HxWxD)
Data can be read using the software and USB data cable supplied. For further information, please contact s.bakker@bavib.nl
| Memory capacity | Active sensors | Interval | Measurement duration |
|---|---|---|---|
| 16,000 readings | crack sensor | 15 minutes | 167 days |
| 16,000 readings | crack sensor humidity air temperature |
15 minutes | 56 days |
| 16,000 readings | crack sensor | 1 hour | 667 days |
| 16,000 readings | crack sensor humidity air temperature |
1 hour | 222 days |
| 64,000 readings | crack sensor | 15 minutes | 667 days |
| 64,000 readings | crack sensor humidity air temperature |
15 minutes | 222 days |